Messages in this thread | | | Date | Sun, 19 Jul 2015 11:55:15 +0100 | From | Jonathan Cameron <> | Subject | Re: [PATCH 3/3] iio: magnetometer: mmc35240: fix SET/RESET sequence |
| |
On 16/07/15 14:30, Daniel Baluta wrote: > On Tue, Jul 14, 2015 at 11:04 PM, Jonathan Cameron <jic23@kernel.org> wrote: >> >> >> On 14 July 2015 15:56:54 BST, Daniel Baluta <daniel.baluta@intel.com> wrote: >>> From: Viorel Suman <viorel.suman@intel.com> >>> >>> The RESET operation invoked in the last instance will align >>> in the natural way all 3 axis and the chip top view. >> What is the result of the bug? >> Just trying to assess urgency of the patch! > > Compass app shows North and South switched. This can be corrected > from mounting matrix though. > Applied. > Daniel. > -- > To unsubscribe from this list: send the line "unsubscribe linux-iio" in > the body of a message to majordomo@vger.kernel.org > More majordomo info at http://vger.kernel.org/majordomo-info.html >
| |