Messages in this thread | | | Date | Thu, 21 May 2015 10:13:50 +0200 | From | Javier Martinez Canillas <> | Subject | Re: [PATCH] pwm: samsung: Use MODULE_DEVICE_TABLE() to include OF modalias |
| |
Hello Thierry,
On 05/14/2015 02:37 AM, Krzysztof Kozlowski wrote: > On 14.05.2015 09:32, Javier Martinez Canillas wrote: >> If the pwm-samsung driver is built as a module, modalias information is >> not filled so the module is not autoloaded. Use the MODULE_DEVICE_TABLE() >> macro to export the OF device ID so the module contains that information. >> >> Signed-off-by: Javier Martinez Canillas <javier.martinez@collabora.co.uk> > > Reviewed-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> > >
Any comments on this patch?
Best regards, Javier
| |