Messages in this thread | | | Date | Sat, 4 Apr 2015 17:34:47 +0200 | From | Wolfram Sang <> | Subject | Re: [PATCH] i2c: cadence: Handling Slave monitor mode |
| |
> > So, it is kind of flooding the bus until the timeout? That is not a single zero > > byte message. > > > It will not flooding the bus until the timeout. Once it fails to access the bus it will be ideal for 15 clock cycles. Master again retrying to access the > Slave immediately after the 15 clock cycles (There is a register in the controller to set the retry value min: 0 cycles, max: 16 cycles).This process will repeat until > The software timeout will happen (1000msec).
Compared to do one access only this is "kind of flooding", no?
[unhandled content-type:application/pgp-signature] | |