lkml.org 
[lkml]   [2015]   [Apr]   [24]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH 17/19] clk: tegra: pll: Fix _pll_ramp_calc_pll logic
Date
This removes the conversion from pdiv to hw, which is already taken
care of by _get_table_rate before this code is run. This avoids
incorrectly converting pdiv to hw twice and getting the wrong hw value.

Signed-off-by: Rhyland Klein <rklein@nvidia.com>
---
drivers/clk/tegra/clk-pll.c | 7 +------
1 file changed, 1 insertion(+), 6 deletions(-)

diff --git a/drivers/clk/tegra/clk-pll.c b/drivers/clk/tegra/clk-pll.c
index 68b42be060c7..fdf322015d76 100644
--- a/drivers/clk/tegra/clk-pll.c
+++ b/drivers/clk/tegra/clk-pll.c
@@ -1038,7 +1038,7 @@ static int _pll_ramp_calc_pll(struct clk_hw *hw,
unsigned long rate, unsigned long parent_rate)
{
struct tegra_clk_pll *pll = to_clk_pll(hw);
- int err = 0, p_div;
+ int err = 0;

err = _get_table_rate(hw, cfg, rate, parent_rate);
if (err < 0)
@@ -1049,11 +1049,6 @@ static int _pll_ramp_calc_pll(struct clk_hw *hw,
err = -EINVAL;
goto out;
}
- p_div = _p_div_to_hw(hw, cfg->p);
- if (p_div < 0)
- return p_div;
- else
- cfg->p = p_div;
}

if (cfg->p > pll->params->max_p)
--
1.7.9.5


\
 
 \ /
  Last update: 2015-04-24 19:21    [W:0.095 / U:0.448 seconds]