Messages in this thread | | | Subject | Re: [PATCH] clocksource: sh_mtu2: Fix multiple shutdown call issue | From | Daniel Lezcano <> | Date | Wed, 28 Oct 2015 10:22:09 +0100 |
| |
On 10/28/2015 02:43 AM, Magnus Damm wrote: > From: Magnus Damm <damm+renesas@opensource.se> > > On the r7s72100 Genmai board the MTU2 driver currently triggers a common > clock framework WARN_ON(enable_count) when disabling the clock due to > the MTU2 driver after recent callback rework may call ->set_state_shutdown() > multiple times. A similar issue was spotted for the TMU driver and fixed in: > 452b132 clocksource/drivers/sh_tmu: Fix traceback spotted in -next > > On r7s72100 Genmai v4.3-rc7 built with shmobile_defconfig spits out the > following during boot: > > sh_mtu2 fcff0000.timer: ch0: used for clock events
Applied.
Thanks !
-- Daniel