lkml.org 
[lkml]   [2014]   [Jul]   [23]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH 1/1] Drivers: scsi: storvsc: Add blist flags
On Wed, Jul 23, 2014 at 04:51:28AM -0700, Christoph Hellwig wrote:
> On Wed, Jul 23, 2014 at 11:04:48AM +0100, Sitsofe Wheeler wrote:
> > OK I've just seen this as I was about to post a similar patch to get
> > discard going on Hyper-V. Will your patches handle Hyper-V pass through devices
> > that support discard? The SSD I have here reports the following in the Linux
> > VM:
>
> I didn't know hyperv also supports pass through, but it should work fine.
> The only thing I'm worried about is real SCSI-2 devices or crappy USB
> devices that don't support EVPD pages and might cause problems. But
> let's ignore that problem for now..

That's good to know (I was worried the device would not be detected as
supporting discard because it doesn't report lbpme and doesn't declare a
conformance version (see below)). Is there a tree with all these updates
in or do they need to be pieced together from this email thread?

Additionally is it worth quirking sd_try_rc16_first on when
BLIST_TRY_VPD_PAGES is present?

# sg_inq /dev/sdc
standard INQUIRY:
PQual=0 Device_type=0 RMB=0 version=0x00 [no conformance claimed]
[AERC=0] [TrmTsk=0] NormACA=0 HiSUP=0 Resp_data_format=2
SCCS=0 ACC=0 TPGS=0 3PC=0 Protect=0 [BQue=0]
EncServ=0 MultiP=0 [MChngr=0] [ACKREQQ=0] Addr16=0
[RelAdr=0] WBus16=0 Sync=0 Linked=0 [TranDis=0] CmdQue=1
[SPI: Clocking=0x0 QAS=0 IUS=0]
length=60 (0x3c) Peripheral device type: disk
Vendor identification: ADATA
Product identification: SSD S510 120GB
Product revision level: 5.2.
Unit serial number: 03205115500300002076

--
Sitsofe | http://sucs.org/~sits/


\
 
 \ /