SubjectRe: [PATCH v2 1/2] i8k: Autodetect maximal fan speed and fan RPM multiplier
Date
On Saturday 20 December 2014 19:07:49 Guenter Roeck wrote:
> On 12/20/2014 09:27 AM, Steven Honeyman wrote:
> > On 20 December 2014 at 17:20, Guenter Roeck <linux@roeck-
us.net> wrote:
> >> I would think that it should be relatively safe
> >> to assume that the first fan always exists
> >
> > That would be a bad idea, as this is definitely not the
> > case:
> >
> > i8k-virtual-0
> > Adapter: Virtual device
> > fan2: 3181 RPM
> > CPU: +43.0°C
> > Ambient: +42.0°C
> > SODIMM: +36.0°C
>
> Well, then he'll have to loop through fans until finding one
> which exists.
>
> Guenter

Ok, I will send new version of patch.

--
Pali Rohár