On Wed, Dec 17, 2014 at 05:45:05PM +0200, Tero Kristo wrote:
> Yea clock mux can be used. However, we don't have support for DRA7
> control module clocks in the DT yet. I have posted patches with
> support towards this a couple of weeks back, but they need some
> revising.
>
> Thus, we maybe need to apply the timer patches as is for now, and
> fix the clock tree a bit later.

Certainly the patches so far fix the system time issue. I don't think
anything else in the clock tree using this clock is that picky about
the clock being of by 0.05% (when using 20MHz SYSCLK1, which I believe
all boards so far do, other than the one board on my desk with a 19.2MHz
clock because we wanted to see what happened). Certainly if someone
does build a baord using either 19.2 or 27MHz as supported in the
documentation, then it becomes more relevant potentially.

But I certainly don't consider fixing the clock tree urgent. I think
we can start shipping products with the clock tree in the current state
(but we couldn't with the system time being that bad, which the patches
so far fix).

--
Len Sorensen


\
 
 \ /