Messages in this thread | | | From | "Lennart Sorensen" <> | Date | Wed, 17 Dec 2014 10:49:11 -0500 | Subject | Re: [PATCH 2/2] ARM: omap5/dra7xx: Fix counter frequency drift for AM572x errata i856. |
| |
On Wed, Dec 17, 2014 at 05:45:05PM +0200, Tero Kristo wrote: > Yea clock mux can be used. However, we don't have support for DRA7 > control module clocks in the DT yet. I have posted patches with > support towards this a couple of weeks back, but they need some > revising. > > Thus, we maybe need to apply the timer patches as is for now, and > fix the clock tree a bit later.
Certainly the patches so far fix the system time issue. I don't think anything else in the clock tree using this clock is that picky about the clock being of by 0.05% (when using 20MHz SYSCLK1, which I believe all boards so far do, other than the one board on my desk with a 19.2MHz clock because we wanted to see what happened). Certainly if someone does build a baord using either 19.2 or 27MHz as supported in the documentation, then it becomes more relevant potentially.
But I certainly don't consider fixing the clock tree urgent. I think we can start shipping products with the clock tree in the current state (but we couldn't with the system time being that bad, which the patches so far fix).