Messages in this thread | | | Date | Wed, 12 Nov 2014 18:20:58 +0100 | From | Oleg Nesterov <> | Subject | Re: [PATCH v2 4/5] x86/mce: Simplify flow when handling recoverable memory errors |
| |
Sorry, I am a bit confused...
On 11/11, Borislav Petkov wrote: > > Roughly speaking, we want to be able to mark a task with the sign of > death and to kill it, if needed.
"it" is current, yes?
So I agree with Andy, task_work_add() can work and you can also pass paddr/restartable to the handler.
But,
> The important part is *before* it > gets to run again.
But it is already running? Perhaps you meant "before it returns to user-mode" ?
Oleg.
| |