Messages in this thread Patch in this message | | | From | Geert Uytterhoeven <> | Subject | [PATCH 1/3] clocksource: sh_tmu: Document R-Mobile r8a7740 binding | Date | Wed, 22 Oct 2014 11:38:27 +0200 |
| |
Compared to the r8a7779, the r8a7740 lacks the input capture register, which is not used by the driver (the current driver already handles the r8a7740 in the non-DT case).
Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> --- Documentation/devicetree/bindings/timer/renesas,tmu.txt | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)
diff --git a/Documentation/devicetree/bindings/timer/renesas,tmu.txt b/Documentation/devicetree/bindings/timer/renesas,tmu.txt index 7db89fb2544411b5..4ae7910af09ffcb4 100644 --- a/Documentation/devicetree/bindings/timer/renesas,tmu.txt +++ b/Documentation/devicetree/bindings/timer/renesas,tmu.txt @@ -1,4 +1,4 @@ -* Renesas R-Car Timer Unit (TMU) +* Renesas R-Mobile/R-Car Timer Unit (TMU) The TMU is a 32-bit timer/counter with configurable clock inputs and programmable compare match. @@ -9,6 +9,7 @@ are independent. The TMU hardware supports up to three channels. Required Properties: - compatible: must contain one or more of the following: + - "renesas,tmu-r8a7740" for the r8a7740 TMU - "renesas,tmu-r8a7779" for the r8a7779 TMU - "renesas,tmu" for any TMU. This is a fallback for the above renesas,tmu-* entries -- 1.9.1
| |