lkml.org 
[lkml]   [2013]   [Jul]   [30]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH] staging: ozwpan: High resolution timers
On Tue, Jul 30, 2013 at 01:31:50PM +0100, Rupesh Gujare wrote:
> Current implementation assumes HZ = 1000 for calculating
> all internal timer intervals, which creates problem on
> platforms where HZ != 1000.
>
> As well we need resolution of less than 10 mSec for heartbeat
> calculation, this creates problem on some platforms where HZ is
> configured as HZ = 100, or around, which restricts us to timer interval
> of 10 mSec. This is particularly found on embedded devices.
>
> This patch moves on to use high resolution timers to calculate
> all timer intervals as it allows us to have very small resolution
> of timer interval, removing dependency on HZ.
>

I am new to this driver. So we batch all the transfers together and
send/recieve them in oz_hcd_heartbeat() every 10msec? It's a
polling interface?

Sorry, if I am completely mis-reading what this driver is doing.

In other words, could you explain what oz_hcd_heartbeat() does.

regards,
dan carpenter



\
 
 \ /
  Last update: 2013-07-30 16:01    [W:0.022 / U:0.948 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site