    Subject[PATCH] regulator: palmas: Remove a redundant setting for warm_reset
    From
    Date
    Current code read "ti,warm_reset" of property twice, and set
    pdata->reg_init[idx]->warm_reset twice. Read and set it once is enough.

    Signed-off-by: Axel Lin <axel.lin@ingics.com>
    ---
    drivers/regulator/palmas-regulator.c | 5 -----
    1 file changed, 5 deletions(-)

    diff --git a/drivers/regulator/palmas-regulator.c b/drivers/regulator/palmas-regulator.c
    index cbaf226..cde13bb 100644
    --- a/drivers/regulator/palmas-regulator.c
    +++ b/drivers/regulator/palmas-regulator.c
    @@ -568,11 +568,6 @@ static void palmas_dt_to_pdata(struct device *dev,
    pdata->reg_init[idx]->mode_sleep = prop;

    ret = of_property_read_u32(palmas_matches[idx].of_node,
    - "ti,warm_reset", &prop);
    - if (!ret)
    - pdata->reg_init[idx]->warm_reset = prop;
    -
    - ret = of_property_read_u32(palmas_matches[idx].of_node,
    "ti,tstep", &prop);
    if (!ret)
    pdata->reg_init[idx]->tstep = prop;
    --
    1.7.9.5




    \
     
     \ /