lkml.org 
[lkml]   [2013]   [Feb]   [26]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH 01/15] staging: omap-thermal: Add print when TSHUT temperature reached
Date
From: Ruslan Ruslichenko <x0191366@ti.com>

To indicate that board was shut down due to TSHUT temperature reached
it is good to print some information message before shutting down.

Signed-off-by: Ruslan Ruslichenko <x0191366@ti.com>
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
---
drivers/staging/omap-thermal/omap-bandgap.c | 3 +++
1 files changed, 3 insertions(+), 0 deletions(-)

diff --git a/drivers/staging/omap-thermal/omap-bandgap.c b/drivers/staging/omap-thermal/omap-bandgap.c
index dcc1448..35b9915 100644
--- a/drivers/staging/omap-thermal/omap-bandgap.c
+++ b/drivers/staging/omap-thermal/omap-bandgap.c
@@ -133,6 +133,9 @@ static irqreturn_t talert_irq_handler(int irq, void *data)
/* This is the Tshut handler. Call it only if HAS(TSHUT) is set */
static irqreturn_t omap_bandgap_tshut_irq_handler(int irq, void *data)
{
+ pr_emerg("%s: TSHUT temperature reached. Needs shut down...\n",
+ __func__);
+
orderly_poweroff(true);

return IRQ_HANDLED;
--
1.7.7.1.488.ge8e1c


\
 
 \ /