lkml.org 
[lkml]   [2013]   [Dec]   [1]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH v2 2/3] bq2415x_charger: Use power_supply notifier for automode
On Mon, Nov 25, 2013 at 08:16:34PM +0100, Michael Trimarchi wrote:
...
> >> So you can read this value without any type of synchronization
> >> with the power_supply_core
> >> and sysfs implementation?
...
> https://lists.ubuntu.com/archives/kernel-team/2013-January/025206.html
>
> I found and equivalent scenario that I was trying to said

That's a good question, actually. Even though in Pali's case the notifier
is atomic (so that we are pretty confident that the object won't be
unregistered), there is still a possiblity of a dead lock, for example. So
notifiers should be careful to not hold any locks, because the other
driver might call get_property(), which might acquire locks.

Thanks,

Anton


\
 
 \ /