Messages in this thread | | | Date | Mon, 25 Nov 2013 11:40:33 -0400 | From | Eduardo Valentin <> | Subject | Re: [PATCHv9 02/20] thermal: introduce device tree parser |
| |
On 25-11-2013 11:31, Mark Rutland wrote: > Any cooling device has a range of cooling states (i.e. different levels > of heat dissipation). For example a fan's cooling states correspond to > the different fan speeds possible. Cooling states are referred to by > single unsigned integers, where larger numbers mean greate heat > dissipation. The precise set of cooling states associated with a device > (as referred to be the cooling-min-state and cooling-max-state > properties) should be defined in a particular device's binding.
OK. Added this to the binding document.
-- You have got to be excited about what you are doing. (L. Lamport)