SubjectRe: [PATCH] I2C: busses: Do not print error message in syslog if no ACK received
From
Date
On Wed, 2013-11-13 at 20:24 +0100, Marek Vasut wrote:
> > On Tue, Nov 12, 2013 at 07:33:40PM +0100, Marek Vasut wrote:
> > > > > That is because if you look at the only caller of this function,
> > > > > which is pch_i2c_wait_for_check_xfer(), you will see that at the
> > > > > only place where pch_i2c_getack() is called there is already
> > > > > pch_dbg():
> > > > >
> > > > > 369 if (pch_i2c_getack(adap)) {
> > > > > 370 pch_dbg(adap, "Receive NACK for slave address"
> > > > > 371 "setting\n");
> > > > > 372 return -EIO;
> > > > > 373 }
> >
> > Sorry i misunderstood that. You are absolutly right, thats the best
> > solution for that. Remove the pch_err at getack so that only the pch_dbg
> > get printed where getack is called. This should be enough information.
>
> No problem ;-)

If this is the approach taken, please coalesce the format.
As is there's a missing space between address and setting.
This should be:

pch_dbg(adap, "Received NACK for slave address setting\n");




\
 
 \ /