Messages in this thread |  | | Date | Tue, 8 Jan 2013 11:16:00 +0000 | From | Mark Brown <> | Subject | Re: [PATCH 2/3] regulator: max8998: Use uV in voltage_map_desc |
| |
On Fri, Dec 28, 2012 at 05:10:20PM +0800, Axel Lin wrote: > Integer division may truncate. > This happens when pdata->buckx_voltagex setting is not align with 1000 uV. > Thus use uV in voltage_map_desc, this ensures the selected voltage won't less > than pdata buckx_voltagex settings.
Applied, thanks. [unhandled content-type:application/pgp-signature] |  |