Messages in this thread | | | Date | Thu, 24 Jan 2013 11:09:53 +0100 (CET) | From | Jiri Kosina <> | Subject | Re: [PATCH 6/6] Drivers: hv: Execute shutdown in a thread context |
| |
On Wed, 23 Jan 2013, K. Y. Srinivasan wrote:
> Execute the shutdown code in a thread context. With recent changes made to the > shutdown code, shutdown code cannot be invoked from an interrupt context. > > Signed-off-by: K. Y. Srinivasan <kys@microsoft.com> > Reviewed-by: Haiyang Zhang <haiyangz@microsoft.com> > --- > drivers/hv/hv_util.c | 12 +++++++++++- > 1 files changed, 11 insertions(+), 1 deletions(-) > > diff --git a/drivers/hv/hv_util.c b/drivers/hv/hv_util.c > index 8b7868a..aceb67f 100644 > --- a/drivers/hv/hv_util.c > +++ b/drivers/hv/hv_util.c > @@ -49,6 +49,16 @@ static struct hv_util_service util_kvp = { > .util_deinit = hv_kvp_deinit, > }; > > +static void perform_shutdown(struct work_struct *dummy) > +{ > + orderly_poweroff(true); > +}
Is there any particular reason for this kind of crazy indentation?
-- Jiri Kosina SUSE Labs
| |