Messages in this thread |  | | Date | Thu, 17 Jan 2013 10:38:30 -0800 | From | Tejun Heo <> | Subject | Re: [PATCH 1/2] init, block: try to load default elevator module early during boot |
| |
Hello, Linus.
On Thu, Jan 17, 2013 at 10:05:53AM -0800, Linus Torvalds wrote: > And here I was really hoping that there was a third patch in the > series that added the warning... > > We don't currently have a "am I an async worker" helper function for > the warning to use, which is something very much up your alley.
Oh yeah, it's coming. I just wanted to finish something else first and, as turning on PF_WQ_WORKER on a rescuer thread has some chance of developing into an obscure difficult-to-trigger and diagnose problem, don't want to hurry it too much.
Thanks.
-- tejun
|  |