Messages in this thread Patch in this message | | | Subject | [PATCH] staging/sb105x: PARPORT config is not good enough must use PARPORT_PC | From | Steven Rostedt <> | Date | Fri, 11 Jan 2013 20:17:01 -0500 |
| |
The sb105x driver calls parport_pc_probe_port() which isn't defined if PARPORT_PC isn't enabled. Protecting it with CONFIG_PARPORT is not good enough, must protect it with CONFIG_PARPORT_PC.
Reported-by: Randy Dunlap <rdunlap@infradead.org> Acked-by: Randy Dunlap <rdunlap@infradead.org> Signed-off-by: Steven Rostedt <rostedt@goodmis.org> --- based off of latest linux-next
diff --git a/drivers/staging/sb105x/sb_pci_mp.c b/drivers/staging/sb105x/sb_pci_mp.c index 131afd0c..9464f38 100644 --- a/drivers/staging/sb105x/sb_pci_mp.c +++ b/drivers/staging/sb105x/sb_pci_mp.c @@ -3054,7 +3054,7 @@ static int init_mp_dev(struct pci_dev *pcidev, mppcibrd_t brd) sbdev->nr_ports = ((portnum_hex/16)*10) + (portnum_hex % 16); } break; -#ifdef CONFIG_PARPORT +#ifdef CONFIG_PARPORT_PC case PCI_DEVICE_ID_MP2S1P : sbdev->nr_ports = 2;
| |