On Thu, Sep 06, 2012 at 10:57:28PM +0200, Fabio Baltieri wrote: > On Thu, Sep 06, 2012 at 05:11:58PM +0200, Kurt Van Dijck wrote: > > > > I also think that led triggers should be available. > > > > > > Right, that's why I think the only way is to use device name. > > > > yes, but it has 2 disadvantages: > > * inconvenient. I like 'can0-tx' much more than any device name > > (Sorry I can't get any real example, I'm not at home now). > > And for usecases where the actual device of the CAN iface is > > important, such setup requires udev to assign the proper iface names. > > Can't argue with that... I'm trying to see how it comes but names like > "can-3-2:1.0-tx" doesn't looks that friendly to me...
"can-3-2:1.0" is an iface name? We must keep default iface names can%d. Only in the usecase that someone wants to name its ifaces according device names, he/she should manually adjust udev rules on his/her system ...
And if the iface is names "can-3-2:1.0", "can-3-2:1.0-tx" _is_ a friendly trigger name.
> > > * extends existing function calls like sja1000 > > Indeed. > > > > > I asked the question because detach & attach leds to interfaces would > > > > indeed break that. > > > > > > Sure? I think that the trigger would be set again on reattach, as > > > default_trigger is checked both in led_cdev probe and > > > trigger_register, see: > > > > > > http://lxr.free-electrons.com/source/drivers/leds/led-triggers.c#L180 > > > > > > I'll try that tonight. > > > > It looks even more inconvenient. It only works as expected when you don't > > change the trigger afterwards, but still it is possible (as should be), > > so the design of trigger is ... wrong. > > example: > > When you put another trigger to a led, and have a proper sequence of > > 'ip link set xxx up' and 'ip link set xxx down', you will end up > > with the default_trigger again. > > I realize I'm looking at unusual scenario's. > > That's not correct, default trigger is going to be set only if there are > no other trigger assigned to the LED, and only on led probe and trigger > probe. > > So, the LED framework is not going to change the trigger if you manually > changed it to something else, and in any case default_trigger assignment > only happens at probe/exit, not when interface is set up/down.
I think you're also arguing against a register/unregister during iface up/down. We agree.