3.6-stable review patch. If anyone has any objections, please let me know.
------------------
From: Stanislaw Gruszka <sgruszka@redhat.com>
commit bf7e1abe434ba9e22e8dc04a4cba4ab504b788b8 upstream.
Some hardware has correct (!= 0xff) value of tssi_bounds[4] in the EEPROM, but step is equal to 0xff. This results on ridiculous delta calculations and completely broke TX power settings.
Reported-and-tested-by: Pavel Lucik <pavel.lucik@gmail.com> Signed-off-by: Stanislaw Gruszka <sgruszka@redhat.com> Acked-by: Ivo van Doorn <IvDoorn@gmail.com> Signed-off-by: John W. Linville <linville@tuxdriver.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
--- drivers/net/wireless/rt2x00/rt2800lib.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
--- a/drivers/net/wireless/rt2x00/rt2800lib.c +++ b/drivers/net/wireless/rt2x00/rt2800lib.c @@ -2395,7 +2395,7 @@ static int rt2800_get_gain_calibration_d /* * Check if temperature compensation is supported. */ - if (tssi_bounds[4] == 0xff) + if (tssi_bounds[4] == 0xff || step == 0xff) return 0; /*
|