Messages in this thread | | | Date | Tue, 30 Oct 2012 09:03:19 +0100 | From | Mathieu Chouquet-Stringer <> | Subject | Re: Nouveau regression between 3.6 and 3.7-rc3: driver stuck at "running init tables" |
| |
On Tue, Oct 30, 2012 at 03:12:59PM +1000, Ben Skeggs wrote: > Not sure what's up with the hang yet, however, I noticed the issue [1] > which is likely causing the error messages from nouveau's i2c code. > With some luck, it'll stop triggering whatever bug is making it hang in > the VBIOS init table parser.
Just tested that and it works (TM). So yeah, that fixed it. Thanks.
Reported-by: Mathieu Chouquet-Stringer <mathieu@csetco.com> Tested-by: Mathieu Chouquet-Stringer <mathieu@csetco.com>
-- Mathieu Chouquet-Stringer mathieu@csetco.com The sun itself sees not till heaven clears. -- William Shakespeare --
| |