Messages in this thread | | | Date | Fri, 05 Nov 2010 18:11:25 +0300 | From | Sergei Shtylyov <> | Subject | Re: [PATCH 4/4] power_supply: isp1704: Detect charger after probe |
| |
Hello.
On 04-11-2010 17:31, Heikki Krogerus wrote:
> If the device is booted up with cable connected, or the > module is loaded after plugging in the cable, the > notification has come and gone, so not relying on it at > probe time. Instead this checks the VBUS level manually > after probe.
> Signed-off-by: Heikki Krogerus<heikki.krogerus@nokia.com> > --- > drivers/power/isp1704_charger.c | 17 +++++++++++++++++ > 1 files changed, 17 insertions(+), 0 deletions(-)
> diff --git a/drivers/power/isp1704_charger.c b/drivers/power/isp1704_charger.c > index 77c11f1..946e43c 100644 > --- a/drivers/power/isp1704_charger.c > +++ b/drivers/power/isp1704_charger.c > @@ -422,6 +422,23 @@ static int __devinit isp1704_charger_probe(struct platform_device *pdev) > > dev_info(isp->dev, "registered with product id %s\n", isp->model); > > + /* > + * Taking over the D+ pullup. > + * > + * FIXME: The device will be disconnected if the it was already ^^^ "the" is not needed here.
WBR, Sergei
| |