Messages in this thread | | | Date | Tue, 27 May 2008 00:36:44 +0200 | From | Jiri Slaby <> | Subject | Re: PROBLEM: Serial error |
| |
On 05/26/2008 11:14 PM, Noel (Sourceforge) wrote: > serial comms error with smsclient >2.6.25 , worked fine up until and > including 2.6.24.7 [...] > 01:0c.0 Serial controller: PLX Technology, Inc. PCI <-> IOBus Bridge > (rev 01) (prog-if 00 [8250]) > Subsystem: Stallion Technologies, Inc. Unknown device f010
Do you have some patched driver or whatever, that this binds?
[...] > Stallion Multiport Serial Driver: version 5.6.0 > Stallion Intelligent Multiport Serial Driver: version 5.6.0 > 0000:01:0c.0: ttyS4 at I/O 0xd880 (irq = 6) is a ST16654 > 0000:01:0c.0: ttyS5 at I/O 0xd888 (irq = 6) is a ST16654 > 0000:01:0c.0: ttyS6 at I/O 0xd890 (irq = 6) is a ST16654 > 0000:01:0c.0: ttyS7 at I/O 0xd898 (irq = 6) is a ST16654 > 0000:01:0c.0: ttyS8 at I/O 0xd8a0 (irq = 6) is a ST16654 > 0000:01:0c.0: ttyS9 at I/O 0xd8a8 (irq = 6) is a ST16654 > 0000:01:0c.0: ttyS10 at I/O 0xd8b0 (irq = 6) is a ST16654 > 0000:01:0c.0: ttyS11 at I/O 0xd8b8 (irq = 6) is a ST16654 <-- phone line > in this port > > > suggestions or assistance appreciated.
The only significant change is ccfea3c98a10b9d4d49b899616a06594ec976d7d could you try to revert it and re-test?
| |