Messages in this thread | | | Date | Wed, 5 Dec 2007 20:31:10 +0000 | From | Pavel Machek <> | Subject | Re: [PATCH 1/2] power: remove POWER_SUPPLY_PROP_CAPACITY_LEVEL |
| |
On Wed 2007-12-12 14:12:56, Andres Salomon wrote: > > The CAPACITY_LEVEL stuff defines various levels of charge; however, what > is the difference between them? What differentiates between HIGH and NORMAL, > LOW and CRITICAL, etc?
On embedded hw, it is quite common that you can sense only 4-or-so levels of battery charge, very non-linear. I suspect that's what capacity_level comes from.
-- (english) http://www.livejournal.com/~pavelmachek (cesky, pictures) http://atrey.karlin.mff.cuni.cz/~pavel/picture/horses/blog.html
| |