Messages in this thread | | | Date | Wed, 28 Sep 2005 06:06:03 -0700 | From | Venkatesh Pallipadi <> | Subject | Re: [PATCH 6/7] HPET-RTC: fix timer config register accesses |
| |
On Wed, Sep 28, 2005 at 09:12:31AM +0200, Clemens Ladisch wrote: > Make sure that the RTC timer is in non-periodic mode; some stupid BIOS > might have initialized it to periodic mode. > > Furthermore, don't set the SETVAL bit in the config register. This > wouldn't have any effect unless the timer was in period mode (which it > isn't), and then the actual timer frequency would be half that of the > desired one because incrementing the comparator in the interrupt > handler would be done after the hardware has already incremented it > itself. > > Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Ack on these two patches. [PATCH 7/7] HPET-RTC: cache the comparator register [PATCH 6/7] HPET-RTC: fix timer config register accesses
Andrew: Please apply.
Thanks, Venki
- To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/
| |