lkml.org 
[lkml]   [2024]   [May]   [8]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
SubjectRe: [Intel-wired-lan] [PATCH v2 2/2] e1000e: fix link fluctuations problem
From
On 07/05/2024 15:31, Andrew Lunn wrote:
> On Fri, May 03, 2024 at 06:18:36PM +0800, Ricky Wu wrote:
>> As described in https://bugzilla.kernel.org/show_bug.cgi?id=218642,
>> Intel I219-LM reports link up -> link down -> link up after hot-plugging
>> the Ethernet cable.
>
> Please could you quote some parts of 802.3 which state this is a
> problem. How is this breaking the standard.
>
> Andrew

In I219-* parts used LSI PHY. This PHY is compliant with the 802.3 IEEE
standard if I recall correctly. Auto-negotiation and link establishment
are processed following the IEEE standard and could vary from platform
to platform but are not violent to the IEEE standard.

En-Wei, My recommendation is not to accept these patches. If you think
there is a HW/PHY problem - open a ticket on Intel PAE.

Sasha

\
 
 \ /