Messages in this thread | | | Date | Sun, 12 May 2024 13:13:04 +0100 | From | Jonathan Cameron <> | Subject | Re: [PATCH v6 4/9] iio: pressure: bmp280: Use unsigned data types for raw sensor data |
| |
On Wed, 8 May 2024 18:52:02 +0200 Vasileios Amoiridis <vassilisamir@gmail.com> wrote:
> The raw sensor data that have not been compensated yet cannot be > signed values, so use unsigned ones. Also, compensated pressure > values cannot be negative so use unsigned also there. > > Also, drop redundant cast of data->t_fine variable from s32 to s32. > > Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com> Looks good to me.
Applied.
| |